News  |  About Us  |  Contact Us

    Our Brands

    ATX PRD Flameproof Plug Socket

    Category: Plugs and Sockets
    Brand: ATX

    Flameproof

    • Zone 1 and 2 - 21 and 22
    • ex  II 2 GD or II 2 G
    • ATEX / IEC
    • IP66 or IP55 – IK10

    Appleton’s ATX PRD Series plugs and sockets provide safe, reliable power in hazardous locations and areas exposed to corrosive chemicals, weather or rough use. They are available 16, 32, 80 and 125 Amp versions for powering portable or stationary equipment, such as lighting and heating systems, conveyors, motor starters, air-conditioning appliances, compressors and pumps.

    ApplicationsFeaturesCatalog Numbers
    • Hazardous areas where plugs and sockets are used with portable or stationary electrical equipment such as lighting and heating systems, conveyors, motor starters, air-conditioning appliances, compressors and pumps.
    • Ideal for hazardous areas where robust, weatherproof equipment is required.
    • Ideal for Zone 1, 2, 21 and 22 hazardous locations such as refineries, pipelines, offshore rigs and other applications in the oil and gas industry.
    General:
    • 16 A:
    1. Flameproof seal with cylindrical spigot joint.
    2. Automatic disconnection of the poles by patented dual-safety device, which ensures the following once the plug is removed from the socket outlet.
    3. Automatic and simultaneous disconnection of each phase in a flameproof chamber.
    4. Disconnection, once power is off, of the pins in the second flameproof chamber.
    5. Cover can be padlocked.
    6. Wall sockets and flush sockets incorporate a safety device that only accepts ATX plugs.
    7. ATX plugs can be used with IEC 60309-2 compliant industrial pin socket outlets in non-hazardous areas.
    • 32 A:
    1. Flameproof seal with cylindrical spigot joint.
    2. Mechanical interlocking device ensures.
    3. Disconnection takes place within the flameproof chamber before the plug is removed from the socket outlet.
    4. The plug cannot be removed when energized.
    5. Straight handle placed on the plug for use with IEC 60309-2 compliant industrial pin socket outlets in non-hazardous areas.
    • 80 A and 125 A:
    1. Interlocking mechanical device which prevents.
    2. The switch from closing until the plug is fully inserted into the wall socket.
    3. The plug from being removed until the switch is off.
    4. Socket outlet supplied with a load break isolating switch, ensuring disconnection with power on.
    5. Switch handle can be padlocked in the “off” position (3 padlocks).
    6. Wall Sockets.
    • 16 A:
    1. Gray painted marine grade aluminum alloy.
    2. 2 x M20 threaded cable entries (1 at the top, 1 at bottom).
    3. Supplied with one M20 plug.
    4. Connection on 2 x 4 mm2 terminals.
    5. Earth terminals: internal and external, with 4 mm diameter screws.
    • 32 A:
    1. Gray painted marine grade aluminum alloy body and.
    2. Cast iron flush socket.
    3. 2 x M25 threaded cable entries (1 at the top, 1 at bottom).
    4. Supplied with one M25 plug.
    5. Connection on 10 mm2 terminals.
    6. Earth terminals: internal and external with 6 mm diameter screws.
    • 80 A:
    1. Gray painted cast iron with marine anti-corrosion treatment.
    2. 1 x M32 threaded cable entry (on the top side).
    3. Connection via 8 mm diameter lug terminals (not supplied).
    4. Internal earth through 35 mm2 connection and external earth through 6 mm diameter screws.
    • 125 A:
    1. Gray painted cast iron with marine anti-corrosion treatment.
    2. 1 x M50 threaded entry (on the top side).
    3. Connection via 8 mm diameter lug terminals (not supplied).
    4. Internal earth through 35 mm2 connection and external earth through 6 mm diameter screws.
    5. Plugs.
    6. All plugs: gray painted marine grade aluminum alloy.
    • 16 A:
    1. 1 cable entry through integrated M25 cable gland.
    2. 9 to 12 mm diameter for the 2P+E plug.
    3. 12 to 15 mm diameter for the 3P+E plug.
    4. 15 to 17mm diameter for the 3P+N+E plug.
    5. Connection on 2.5 mm2 maximum terminals.
    • 32 A:
    1. 1 cable entry via integrated cable gland diameter 17 to 22 mm.
    2. Connection on 6 mm2 maximum terminals.
    • 80 A:
    1. 1 cable entry via supplied cable gland diameter 18 to 28 mm.
    2. Connection on 16 mm2 maximum terminals.
    • 125 A:
    1. 1 cable entry via supplied cable gland diameter 30 to 36 mm.
    2. Connection on 35 mm2 maximum terminals.
    94403
    94404
    94406
    94415
    94416
    94420
    94422
    94424
    94425
    94426
    94427
    94428
    94429
    94430
    94458
    94460
    94463
    94467
    94468
    94480
    94667
    94693
    PRD316FBB
    PRD316FBC
    PRD316FPB
    PRD316FPC
    PRD316FYB
    PRD316FYC
    PRD316PB
    PRD316PP
    PRD316PY
    PRD316RB
    PRD316RP
    PRD316RY
    PRD412PR
    PRD412RR
    PRD416FRB
    PRD416FRC
    PRD416PR
    PRD416RR
    PRD432FRB
    PRD432FRC
    PRD432PR
    PRD432RR
    PRD480PR
    PRD480RR
    PRD516FRB
    PRD516FRC
    PRD516PR
    PRD516RR